™INSTALLER: Leave this manual with the appliance.CONSUMER: Retain this manual for future reference.INSTALLATEUR : Laissez cette notice avec l'app
10MAINTENANCE (See Maintenance Schedule, Page 26)Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they sho
11NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 5 5. Position the door in front of the firebox open-ing with the bottom of the door held a
12NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.REFERENCEFirebox Accessories / PartsCat. No. Model No. Description88L53 FGE Bag of Glowing Ember
13NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ELDV3530 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front
14NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ELDV4035 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front
15NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log,
16NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY)Flame Appearance and sootingProper flame appearanc
17NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS• Air shutter adjustment should only be performed by a quali-fied professional s
18NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.TP-THTPTHOPTIONAL APPLIANCE-MOUNTED ON/OFFSWITCHBK/W(1)BK/W(1)WALL-MOUNTED ON/OFF SWITCH (OPTION
19NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ACCESSORY COMPONENTSRemote Control Kit, StandardCat. No. Model No. DescriptionH0249 RCL Remote C
2 Safety and Your Fireplace To prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.To o
20NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ACCESSORY COMPONENTS CONTINUEDStyle View Doors -Style View Doors come in 2 beautiful styles. The
21NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Bag of Glowing EmbersBag of Volcanic StoneReplacement ember materials or volcanic stone are avai
22NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVEFOR YOUR SAFETY READ BEFORE LIGHTINGA. This applianc
23INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT INSTRUCTIONS D'ALLUMAGEPOUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGEA. Cet appare
24A. When lighting the appliance, follow these instructions exactly.B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell
25INSTRUCTIONS D’ALLUMAGE — ELECTRONICINSTRUCTIONS D’ALLUMAGEPOUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGEA. Lorsque vous allumez l’ap
26MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDUREInspecting/Cleaning Burner, Logs and ControlsQualified Service Technician Inspect valve and ensure it
27SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION1. Spark igniter will not light pilot after repeated triggering of igniter button. WARNING: if the pilot
28TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEMSYMPTOM POSSIBLE CAUSES CORRECTIVE ACTIONCheck voltage on AC terminals of module an/or batteries. The
29NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.REPLACEMENT PARTS LISTGas Controls - SIT MillivoltItem No.Description Natural Gas Propane GasPar
3 Afin d'éviter de vous brûler gravement ou de vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct ave
30NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.REPLACEMENT PARTS 133033311542110113235341412134012415343844161742456792120232224NOTE: DIAGRAMS
Printed in U.S.A. © 2006 Lennox Hearth ProductsP/N 875030M REV. E 02/2011Lennox Hearth Products reserves the right to make changes at any time, wi
4Important Safety InformationWARNING: Do not operate appliance with the glass front 1. removed, cracked or broken. Replacement of the glass should be
5NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec
6NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.General InformationThe fireplace models covered in this manual are direct-vent sealed combustion g
7NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Orifice Sizes - Sea Level to High Altitude(All Models): These appliances are tested and approved
8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Gas Controls/Control Compartment AccessThe gas controls can be found behind the control compartme
9NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 2 - SIT Millivolt Gas ValveVariable FlameHeight AdjustmentManifold PressurePortInletPress