EPA Wood-Burning Fireplace
P/N 850,038M REV. B 02/2007
MONTEST
MODEL
MONTECITO ESTATE
This installation manual will enable you to obtain a safe, efficient and de-
pendable installation of your fireplace system. Please read and understand
these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
INSTALLATION AND
OPERATING INSTRUCTIONS
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Listed to standards:
ULC-S610 & UL-127
Report No. 304-7213
EPA Cert. No. 609
WARNINGS
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
If small children are present in the home, it
is recommended that this appliance be fitted
with a Firescreen kit. See Page 20 for ordering
information.
WARNINGS
The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
Install the fireplace only as described in these
instructions.
PIMONTEST REV. 1
LENNOX HEARTH PRODUCTS
D
R
A
F
T
02-26-2007
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - 02-26-2007

EPA Wood-Burning FireplaceP/N 850,038M REV. B 02/2007MONTESTMODELMONTECITO ESTATE™ This installation manual will enable you to obtain a safe, effici

Page 2

1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fir

Page 3 - CONGRATULATIONS!

Figure 1713” x 13”10’ Max.10’ Max.Rain CapFlashing CollarFlashingRoof SupportAtticRadiation ShieldNon-CombustibleFlameproofFacing56” Min.68” Min.Figur

Page 4 - COMBUSTION CONTROLS

OUTSIDE AIR KITIt is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and ar

Page 5 - CAUSES AND TROUBLESHOOTING

8. A rain cap must be installed on top of the chimney. Failure to install a rain cap may cause corrosion problems.9. Cut and frame square holes in all

Page 6 - Dealing With a Chimney Fire

CHIMNEY INSTALLATION INSTRUC-TIONS1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22). Use a plumb

Page 7 - WARNINGS

Roof Down Slope Hole SizeDEGREE OF SLOPE Secure Temp™ S2100+ Nova Temp™ HT6000+ Secure Temp GXACBIRoof Pitch 7” 7”0 * 15” (380 mm) 15” (380 mm)2/12

Page 8 - COLD CLIMATE INSTALLATIONS

OFFSET CHIMNEY INSTALLATIONThe minimum chimney height when using elbows is:Chimney ElbowOffset & HeightTwo Lengths Between Elbows8” 12” 18” 24” 36

Page 9 - Fireplace

Figure 28OFFSET CHIMNEY INSTALLATIONRain CapCollarRoof FlashingOffset SupportInsulated WallRadiation ShieldFraming2” x 3”Figure 29Roof SupportNote: In

Page 10 - IMPORTANT

ANGLED WALL RADIATION SHIELD(XRSMI30 and AC10RSMI30)When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wa

Page 11 - Outlet Grill

INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATIONWARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimne

Page 12 - OUTSIDE AIR KIT

WARNINGTo avoid the risk of damaging fireplace materials and increas-ing the risk of fire, do not use the fireplace to cook or warm food. WARNI

Page 13 - THE CHIMNEY SYSTEM

CHIMNEY - PARTS AND COMPONENTS LISTSSecure Temp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System)Galvanized (7” ID & 11”

Page 14 - CHIMNEY INSTALLATION

ACBI Chimney*(7” I.D., 13” O.D. AC - Air Cooled) * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where te

Page 15 - OFFSET CHIMNEY INSTALLATION

CLEARANCE TO COMBUSTIBLESThe following clearances meet the minimum requirements for a safe installation:• Side wall (fireplace front): 24” (4

Page 17

Printed in Canada © 2006 by LENNOX HEARTH PRODUCTSP/N 850,038M REV. B 02/2007 The manufacturer reserves the right to make changes at any time, wi

Page 18 - CHIMNEY SUPPORT INSTALLATION

TABLE OF CONTENTSSafety Rules ...Page 2 Introduction ...Page 3Parts Required

Page 19

The combustion air control should be opened before opening the doors to minimize the possi-bility of back draft coming into the room (Figure 1-A) More

Page 20

The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar-ranging

Page 21

Figure 5IMPORTANT CAUTIONSA. Do not block the hot air vents to the fire-place as this will cause the fireplace to overheat.B. Never use gasoline, k

Page 22 - GX (7” dia)

DOOR INSTALLATIONThe doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male p

Page 23

FIREPLACE INSTALLATIONLocating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows,

Page 24

Figure 11 Insulated Chase Construction7 Ft. Min.Attic RadiationShieldRoof SupportStorm CollarFlashingDrywall or Any Rigid Material 2” x 4”1/2” Plywood