INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment vous
trouvez.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d’incindie ou d’explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
INSTALLATION AND OPERATION
Ce manuel d’installation est disponible en francais, s implement en faire
la demande. Numéro de la pièce 775222CF.
MODELS
US
Portland
P/N 775222M REV. F 09/2011
DIRECT-VENT
VISION™
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certied kit is used.
WARNING
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
VISN-25/35 SDVSS-25/35
This Gas Stove is factory equipped for 35,000 BTU input and can be converted to
25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).
OTL Report No. 050-S-16b-5
Page view 0
1 2 3 4 5 6 ... 33 34

Summary of Contents

Page 1 - AVERTISSEMENT

INSTALLER: Leave this manual with the appliance.CONSUMER: Retain this manual for future reference.INSTALLATEUR: Laissez cette notice avec l'ap

Page 2 - CONGRATULATIONS!

10NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Pipe ClearancesAll installations using a vertical termination cap must maintain one inch clearan

Page 3

11Installing Door Trim And Spring HandleCAUTION: Always ensure that plated surfaces are clean and free of fingerprints before lighting stove. Fingerpri

Page 4

12NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.7. Place the left log on burner supports with the charred surface facing up. The left log will o

Page 5

13NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.9. Set center log on support with charred surface toward you and rest against the rear log.Vent

Page 6 - SMOKE DETECTORS

14Vent Parts ListSecure Vent™ direct-vent pipe by Security Chimneys™* may be used with this appliance. Please see the lists below to verify the compon

Page 7 - NEW YORK CITY, NEW YORK (MEA)

15NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Storm CollarVertical TerminationCapCeiling F

Page 8

16NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Horizontal TerminationsThe shaded areas in the diagram below show all allowable combinations of

Page 9 - Figure 3

17NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Exterior Horizontal Vent Termination Clearance Requirements V V V V V F C B B A B H M I X V D V

Page 10

18Gas Line InstallationThis stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In

Page 11

19NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.INSTALLER INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installers responsibili

Page 12

2CONGRATULATIONS!When you purchased your new gas stove, you joined the ranks of thousands of individuals whose answer to their home heat-ing needs refl

Page 13 - Figure 13

20NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Operating InstructionsPre-Lighting ChecklistBe sure to check these items before the initial

Page 14 - Figure 15

21NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.10. After pilot is lit, turn gas control knob counterclockwise .2 to “ON.” Kn

Page 15 - 14” Snorkel

22NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 25Air Shutter AdjustmentCAUTION: Air shutter is hot while the appliance is operating and

Page 16 - Figure 20

23NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.-Operating OptionsYour stove comes equipped with an “On/Off” rocker switch used to turn the burn

Page 17 - Figure 21

24NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.CAUTION: Wear gloves and safety glasses for protection while doing required maintenance.Verify

Page 18 - Knob (HI/LO)

25NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Glass DoorOnly doors certified with the appliance shall be used.Seules des portes certifiées p

Page 19

26NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Fuel ConversionConverting the stove between natural gas (NG) and propane (LP) can be accomplishe

Page 20

27TROUBLESHOOTINGNOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in th

Page 21 - WARNINGS

28NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Wire Harness DiagramCAUTION: Label all wires prior to disconnection when servicing controls. Wi

Page 22 - Shutter Adjustment Handle

29 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this ap

Page 23

3IMPORTANT SAFETY AND WARNING INFORMATION WARNING Young children should be carefully supervised when they are in the same room as the appliance.

Page 24 - WARNING

30NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Trim Kits (ref. form #775290M)Kits Include: Matching Trim for Glass, Louvers and Ash LipCat. No.

Page 25 - ATTENTION

31NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ALCOVE DIMENSIONS - DIMENSIONS – ALCOVEMAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm)MINIMUM WID

Page 26

32NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.CAUTION: YOUR LENNOX GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE. STOP! Read

Page 27

33NOTES

Page 28 - SPEED CONTROL SWITCH

34Printed in U.S.A. © 2007 Lennox Hearth ProductsP/N 775222M REV. F 09/2011Lennox Hearth Products reserves the right to make changes at any time, w

Page 29 - AVERTISSEMENT

4FOR YOUR SAFETY do not install or operate this appliance without first reading and understanding this manual. Any installation or operation of the a

Page 30

5NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec

Page 31 - CAUTION:

6• Must conform with all local, state and national installation codes. In the absence of local codes, the installation must conform with National Fue

Page 32

7Installation of these appliances are approved for installation in New York City in the US state of New York (MEA#: 138-07-E).CODES AND APPROVALSCert

Page 33

8* Other approved chimney brand is Simpson Dura-Vent DV-GS.PRE-INSTALLATIONRATINGSVISN-35 / SDVSS-35 VISN-25 / SDVSS-25NATURAL GAS LP GAS NATURAL GAS

Page 34

9NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.14-7/8”(378mm)18-1/2”(470mm)32-1/2”(826mm)Rear Vent DimensionsDimensionsThe gas line attaches to