Lennox-hearth X-FIRES-1000-LP User Manual

Browse online or download User Manual for Kiln Lennox-hearth X-FIRES-1000-LP. Lennox Hearth X-FIRES-1000-LP User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer
(Protects Against Burns) . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
[EN FRANÇAIS] L’information de sûreté importante . . . . . . . . . . . . 34
[EN ESPAÑOL] Información importante de seguridad. . . . . . . . . . . . 34
WHAT'S INSIDE
P/N 506023-01 Rev. D 04/2012
MODELS
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air section in this manual.
INSTALLATION AND OPERATION INSTRUCTIONS
INSTALLER: Leave this manual
with the appliance.
CONSUMER: Retain this manual
for future reference.
INSTALLATEUR : Laissez cette
notice avec l'appareil.
CONSOMMATEUR : Conservez cette
notice pour consultation ultérieure.
DONT
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
Wait...
F
R
E
E
See Page 2 For Details
SAFETY
GUARD
PROTECTS AGAINST BURNS
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING: If the information in these instructions is
not followed exactly, a re or explosion may result
causing property damage, personal injury or death.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d’incindie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
WARNING
/
AVERTISSEMENT
/
AVISO
Catalytic Vent-Free Fireplaces
X-FIRES™ 1000 Models
X-FIRES 1000-NG and X-FIRES 1000-LP
OTL Report No. 317-F-10-5
US
Portland
Manufacturer: Focal Point Fires plc. United Kingdom
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - AVISO

Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety and Your Fireplace . . . . . . . . . . . . . . .

Page 2 - Your Fireplace

10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALENon-concealed gas connections may be made using the entry points at either end of the firebox or

Page 3 - La sécurité et

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE11After having selected the final mounting position of the appliance, tak ing into account the site

Page 4 - Important Safety Information

12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALEIt is recommended that the burner height, where possible, should be approximately 4 ft

Page 5 - Warranty Information

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE13CHECKING THE BURNERThere are no imitation fuel bed components, such as logs or rocks, to

Page 6 - General Information

14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALESPARK GAPThe gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a

Page 7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE15 WARNING Any change to this heater or its controls can be dangerous. WARNING No

Page 8

16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALECATALYSTS WARNING Do not block the catalysts or the appliance outlet grill. Blockage may ca

Page 9 - CAUTION

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE17FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A F

Page 10 - PREPARING THE APPLIANCE

18X-Fire 1000 - H8283 607251-21607042-01506019-71TROUBLESHOOTING GUIDEPROBLEM CORRECTIVE ACTIONIgniter sparks but pilot does not light • No gas to P

Page 11 - X-FIRES 1000

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE19REPLACEMENT PARTS - X-FIRES™ 10005415Hardware121259b69a7810111314See ordering instructions on Pag

Page 12 - FITTING THE SURROUND ASSEMBLY

2Safety and Your Fireplace To prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.To or

Page 13 - IMPORTANT

20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALEPOSITIONING OF FIELD REMOVABLE PARTS WARNING Failure to position the parts in accordance wi

Page 14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE21ACCESSORIES - X-FIRES™ 1000X-FIRES 1000 Surround KitsCat. No. Model Description Ship. Wt. Ship. V

Page 15

22Note: The actual dimensions are shown in millimeters. The fractional dimensions are converted from millimeters and are rounded to the nearest 1/16”

Page 16

23NOTES

Page 17 - ‘OFF’ position

24Printed in U.S.A. © 2007 Lennox Hearth ProductsP/N 506023-01 REV. D 04/2012Lennox Hearth Products reserves the right to make changes at any time,

Page 18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE3 Afin d'éviter de vous brûler gravement ou de vous blesser, installez une grille ou une barr

Page 19 - Hardware

4Important Safety Information1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. 2. Do not use this appliance if any

Page 20

5Appliance Installation, Service, and Maintenance NoticesWARNING: Improper installation, adjustment, alteration, service or maintenance can cau

Page 21 - SPECIFICATIONS

6This appliance is a high efficiency, unvented, flame effect gas heater. It provides radiant and convected warmth both efficiently and safely utilizing

Page 22 - REGULATOR GAS ENTRY POINT

7PACKAGING LISTQuantity DescriptionFireplace 1 Firebox, burner assembly and wall mounting plate 1 Installation and Operation Manual 1 Warranty

Page 23

8COMBUSTION AND VENTILATION AIRThis heater shall not be installed in a confined space or unusually tight construction unless provisions are provided fo

Page 24

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE9SITE REQUIREMENTSThis appliance is designed to be wall-hung. Do not recess any part of the applian

Related models: X-FIRES-1000-NG

Comments to this Manuals

No comments