This manual will enable you to obtain a safe, efficient and dependable
installation and operation of your electric fireplace. Please read and
understand these instructions before beginning your installation.
Do not alter or modify this fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace and accessories, may void the warranty,
listings and approvals of this system and could result in an unsafe and
potentially dangerous installation.
IMPORTANT! IF OPTIONAL GLASS DOORS ARE PURCHASED, TO
ASSURE PROPER ALIGNMENT, INSTALL THIS FIREPLACE IN A
SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY
AT SIDES. THIS APPLIANCE IS MOUNTED ON RUBBER FEET TO
ENSURE ADEQUATE AIR CIRCULATION BENEATH FIREPLACE.
DO NOT BLOCK AIRFLOW AT THE BOTTOM AIR INTAKES.
INSTALLER: DO NOT DISCARD THIS MANUAL
PLEASE LEAVE FOR THE HOMEOWNER
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
Lennox™ electric fireplaces are designed for use as a decora-
tive appliance and/or as a supplemental heater. They are not
intended for continuous use as a primary heat source.
A French manual is available upon request. Order P/N 775,172CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 775,172CF.
INSTALLATION AND
OPERATION INSTRUCTIONS
LENNOX HEARTH PRODUCTS
Report # C1482763
MPE-36R
C
US
®
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - PLUS SERIES

36" Electric FireplaceP/N 775,172M REV. G 04/2007MODEL:SAVE THESE INSTRUCTIONSFOR FUTURE REFERENCEMERIT™ PLUS SERIESThis manual will enable you

Page 2 - READ THIS MANUAL IN ITS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.10WIRING DIAGRAM - 120 VOLTWiring diagrams are provided here for reference purposes only. This inform

Page 3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.11WIRING DIAGRAM - 240 VOLTWiring diagrams are provided here for reference purposes only. This inform

Page 4 - FIREPLACE SPECIFICATIONS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.125 VGROUNDINSIDEPOWER ON/OFF SWITCH (ON CONTROL PANEL)POWER ON/OFF SWITCH (OPTIONAL WALL SWITCH)OUTSI

Page 5 - IMPORTANT

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.13Installing Wall Thermostat(optional kit, see Page 18)Wire the wall thermostat prior to installing th

Page 6 - MANUAL CONTROL PANEL

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.14Power On/Off Wall Switch Installation(optional kit, see Page 18)Wire the wall switch prior to instal

Page 7 - CAUTIONS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.15TROUBLESHOOTINGSymptom Possible Causes Who Performs Corrective ActionCorrective Action1. Fireplace

Page 8 - CAUTION

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.16REPLACEMENT PARTSITEMNO.DESCRIPTION MPE-36RCAT. NO. QTY1Bulb Kit, (10 Each 35w Halogen)H1623 12Side

Page 9

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.17REPLACEMENT PARTS COMPONENT DIAGRAMS - MPE-36R8b2314161114256678a121315 1917Front ViewPOWER�ON/OFF�D

Page 10 - WARNING

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.18ACCESSORY COMPONENTSThe following items are available for use with this appliance.Cat. No. Model D

Page 11

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.19NOTES

Page 12 - POTENTIOMETER

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.2IMPORTANT SAFETY AND WARNIING INFORMATIONREAD THIS MANUAL IN ITS ENTIRETY AND UNDERSTAND THESE RULES

Page 13 - (optional kit, see Page 18)

Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2004P/N 775,172M REV.G 04/2007The manufacturer reserves the right to make changes at any time, without n

Page 14

WARNING Do not install or operate this fire-place through a switch wired in the 120 VAC or 240 VAC circuits. The only approved wiring for a sw

Page 15 - TROUBLESHOOTING

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.4FRAMING SPECIFICATIONS37-5/8"(954 mm)24 "(610 mm)14-7/8"(32 mm)5-1/8 "(130 mm)36

Page 16 - REPLACEMENT PARTS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.5Mantel Clearance: Combustible and Non-com-bustible mantels may be installed at any height above the t

Page 17 - Front View

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.6MANUAL CONTROL PANEL OPERATION(refer to Figures 5 & 6)Once this appliance has been properly insta

Page 18

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.7• When using the remote control, the power on/off switch inside the body and the wall switch (option

Page 19

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.8Figure 9MAINTENANCEThis appliance has been designed to provide many years of trouble-free service. Th

Page 20 - REV.G 04/2007

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.9Replacing Light Bulbs b. Flame Cylinder Bulbs i. Remove Brick panel, following proce-dure on Page