Vent Parts List
Secure Vent direct-vent pipe by Security Chimneys* may be used with
this appliance. Please see the lists below to verify the components avail-
able from each direct-vent pipe manufacturer. Snorkel terminations are
available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Security™ Secure Vent 6-5/8”x 4” Pipe
Part Number Description
SV4LC 6” Pipe Length
SV4L12 12” Pipe Length
SV4L24 24” Pipe Length
SV4L36 36” Pipe Length
SV4L48 48” Pipe Length
SV4LA 6” Pipe, Adjustable
SV4LA12 12” Pipe, Adjustable
SV4FA Flashing, 1/12 to 6/12 Roof Pitch
SV4FB Flashing, 7/12 to 12/12 Roof Pitch
SV4RSM Wall Radiation Shield
SV4E46 45º Elbow
SV4E90 90º Elbow
SV4VS Vinyl Shield Protector
SV4FC Storm Collar
SV4CGV Vertical Termination Cap
SV4BF Firestop
SV4CHC Horizontal Termination Cap
SV4STC36 Snorkel Termination Cap (36”)
SV4STC14 Snorkel Termination Cap (14”)
SV4BM Wall Band
Simpson Dura-Vent GS 6-5/8”x 4” Pipe
Part Number Description
908 6” Pipe Length
907 9” Pipe Length
906 12” Pipe Length
904 24” Pipe Length
903 36” Pipe Length
902 48” Pipe Length
911 11” to 14-5/8” Pipe, Adjustable
942 Wall Thimble
940 Rnd Support Box/Wall Thimble Cover
941 Cathedral Ceiling Support Box
943 Flashing, 0/12 to 6/12 Roof Pitch
943S Flashing, 7/12 to 12/12 Roof Pitch
945 45º Elbow
990 90º Elbow
950 Vinyl Siding Standoff
953 Storm Collar
963 Ceiling Firestop
988 Wall Strap
981 Snorkel Termination (36”)
982 Snorkel Termination (14”)
984 Horizontal Termination Cap
985 Horizontal Termination Cap (High Wind)
980 Vertical Termination Cap
991 Vertical Termination Cap (High Wind)
Horizontal Vent Installation
Venting terminals may not be recessed into a wall or siding.
1. Set the unit in the desired location. Check whether or not wall studs
are in the way when the venting system is attached. If wall studs are
in the way, you may want to adjust the location of the unit.
2. Any stove that is horizontally terminated and has a vertical section
of pipe off the top of the stove, that first section of pipe must be a
minimum of 18” long.
3. All horizontally terminated vent installations may only use 6-5/8”x 4”
Security™ Secure Vent pipe*.
4. Assemble the desired combination of pipe and elbow(s) to the appli-
ance adapter with pipe seams facing down. Offsetting the pipe seams
as double seams in one place will cause the outer pipe to take an oval
shape.
5. When this pipe passes through a wall, a wall thimble - Simpson #942
or Security™ #SV4RSM - is required. The hole in the wall for the
wall thimble should be 9-1/4”x 10-1/4”. If the wall being penetrated
is constructed of non-combustible material (i.e. masonry block or
concrete), a 7” diameter hole is acceptable and a wall thimble is not
required.
6. Horizontal runs of vent pipe must be supported every 3 feet. Wall
straps - Simpson #988 or Security™ #SV4BM - are available for this
purpose.
7. If the vent passes through a ceiling or floor, a firestop - Simpson #963
or Security™ #SV4BF - is required.
8. Also note that venting terminals shall not be recessed into a wall or
siding. If installing the termination cap on a wall covered with vinyl
siding, a vinyl siding standoff - Simpson #950 or Security™ #SV4VS
- or furring strips must be used to ensure that the termination cap is
not recessed into the siding.
9. The horizontal run of vent should have a 1/4” rise for every 12” of run
toward the termination. Never allow the vent to run downward. This
could cause high temperatures and may present the possibility of a
fire.
10.If the wall being penetrated is constructed of noncombustible material,
such as masonry block or concrete, an 7” diameter hole is acceptable
and a wall thimble is not required..
11. The location of the horizontal vent termination on an exterior wall must
meet all local and national building codes and must not be blocked
or obstructed. For allowable external vent termination locations (see
Page 17).
12. Allowable clearances from the vent pipe to combustible materials must
be maintained. See Page 9 for these clearances.
13. Do not locate the termination cap where it may be blocked by shrub-
bery or snow.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.